Implementing ABCD studyⓇ MRI sequences for multi-site cohort studies: Practical guide to necessary steps, preprocessing methods, and challenges

Unknown authors · 2024
hash_id: a54a4e853b554a8dc00a4c6b2a704e018537cd4594a3b4024629e5b669f4922b · DOI: 10.1016/j.mex.2024.102789

Large multi-site studies that combine magnetic resonance imaging (MRI) data across research sites present exceptional opportunities to advance neuroscience research. However, scanner or site variability and non-standardised image acquisition protocols, data processing and analysis pipelines can adversely affect the reliability and repeatability of MRI derived brain measures. We implemented a standardised MRI protocol based on that used in the Adolescent Brain Cognition Development (ABCD) Ⓡ study in two sites, and across four MRI scanners. Twice repeated measurements of a single healthy volunteer were obtained in two sites and in four 3T MRI scanners (vendors: Siemens, Philips, and GE). Imaging data included anatomical scans (T1 weighted, T2 weighted), diffusion weighted imaging (DWI) and resting state functional MRI (rs-fMRI). Standardised containerized pipelines …

Reference & gravity metrics

Citations
0
Citations / yr
0.00
RCR
Mass
0.00
Depth
0.00
Momentum
0.000
Burn rate
0.00 ATP/day
Start price
25.00 ATP

Secondary-market trade history

No secondary-market trades recorded for this Volta yet.

References (0)

No outbound references recorded.

Cited by (1)

Cortical thickness in brain imaging studies using FreeSurfer and CAT12: A matte… secondary