SARS-CoV-2 antigen rapid detection tests: test performance during the COVID-19 pandemic and the impact of COVID-19 vaccination

Unknown authors · 2024
hash_id: a61aceb874cf741f96d347d6e0087c73f6cc8a0eb3010578e208ec20b2f4bdde · DOI: 10.1016/j.ebiom.2024.105394

BACKGROUND: SARS-CoV-2 antigen rapid detection tests (RDTs) emerged as point-of-care diagnostics alongside reverse transcription polymerase chain reaction (RT-qPCR) as reference. METHODS: In a prospective performance assessment from 12 November 2020 to 30 June 2023 at a single centre tertiary care hospital, the sensitivity and specificity (primary endpoints) of RDTs from three manufacturers (NADAL®, Panbio™, MEDsan®) were compared to RT-qPCR as reference standard among patients, accompanying persons and staff aged ≥ six month in large-scale, clinical screening use. Regression models were used to assess influencing factors on RDT performance (secondary endpoints). FINDINGS: Among 78,798 paired RDT/RT-qPCR results analysed, overall RDT sensitivity was 34.5% (695/2016; 95% CI 32.4-36.6%), specificity 99.6% (76,503/76,782; 95% CI 99.6-99.7%). Over the pandemic course, sensitivity decreased in line …